Components
- Methacrylate-based blend with UV initiator One-component system, Styrene-free
Properties
- tack-free
- high chemical resistance (see TDS for test results)
- high mechanical properties
- adhere to concrete, steel, PVC
Methacrylate Resins
Ultracure has been developed for the UV-cured pipe rehabilitation process, suitable for inversion lining repair. It can be used as a matrix material for in-situ or for pre-impregnated composites.

Application focus
Ultracure has been developed for the UV-cured pipe rehabilitation process, suitable for inversion lining repair.
System type
Ultracure is a methacrylate-based, one-component system that includes the necessary UV initiator and is completely Styrene-free.
Viscosity
3000 ± 400 cP
Primary benefit
premium performance UV resin
Characterization
Ultracure has been developed for the UV-cured pipe rehabilitation process, suitable for inversion lining repair. It can be used as a matrix material for in-situ or for pre-impregnated composites.
Composition
Ultracure is a methacrylate-based, one-component system that includes the necessary UV initiator and is completely Styrene-free.
Components
Properties
Technical Data
To assess chemical resistance, we introduced a rating system from 1 to 5, with 5 indicating the highest resistance.
Normal petrol
5
Super petrol
5
CaCl2- saturated
5
Diesel
5
Acetic acid 10%
5
Acetic acid 20%
4
Ethanol
5
Oil
5
Phosphoric acid 10%
5
H2O2 30%
3
H2O2 5%
5
H2SO4 10%
5
H2SO4 20%
5
H2SO4 40%
5
HCl 10%
5
HCl 37%
5
HNO3 10%
5
HNO3 20%
5
HNO3 40%
3
IPA
5
MgCl2- saturated
5
NaCl 20%
5
NaOH 10%
5
NaOH 30%
5
NaOH 50%
5
Lactic acid 10%
5
Toluol
5
Important product note
Product information on this page is provided for general informational purposes only. Performance depends on application, site, operating conditions, and compatibility with the rest of the system. If a Polinvent product is used together with third-party equipment, liners, resins, curing units, or other components, that combination requires written Polinvent approval. Otherwise, the customer must verify suitability and bears the integration and project-performance risk. Review the applicable SDS, TDS, and product manual where relevant. Binding specifications arise only from the Confirmed Order and the written technical documentation supplied by Polinvent.